El Puente de Santolea
Download PDF data sheet
Particulars
Owner: unknown
Designer: Cygsa
Contractor: UTE, Isolux-Corvian-Corsan, Copisa
Statistics
Type: Gravity
Purpose(s): Irrigation
Reservoir capacity: 18 m3x106
Height: 35 metres
Length: 203 metres
Volume of RCC: 65 m3x103
Total volume: 70 m3x103
Construction Dates
Start of Project: —/09 (— 2009)
Start of RCC: 04/10 (April 2010)
End of RCC: 02/11 (February 2011)
End of Project: 03/11 (March 2011)
Country: Spain
River: Guadalope
DMS Co-ordinates: 40˚44'49.69"N, 0˚20'34.88"W
DD Co-ordinates: 40.747135, -0.343022
Facings
Upstream
Slope | Type |
---|---|
0.20 | RCC against formwork (GEVR/GE-RCC) [stepped face] |
Downstream
Slope | Type |
---|---|
0.60 | RCC against formwork (GEVR/GE-RCC) [stepped face] |
Spillway
Slope | Type |
---|---|
0.60 | RCC against formwork (GEVR/GE-RCC) [stepped face] |
Placement
Layers (mm) | Lifts (mm) |
---|---|
300 | 300 |
Cementitious material
Cement (kg/m3) |
---|
65 |
Pozzolan (kg/m3) | Pozzolan Type |
---|---|
153 | Low-lime flyash (ASTM Class F) |