S.W. Freese (formerly Stacy - spillway)
Download PDF data sheet
Particulars
Owner: unknown
Designer: Freese & Nichols, Fort Worth, Texas
Contractor: Brown & Root, Houston
Statistics
Type: Gravity
Purpose(s): Water Supply
Reservoir capacity: 700 m3x106
Height: 31 metres
Length: 173 metres
Volume of RCC: 89 m3x103
Total volume: 158 m3x103
Construction Dates
Start of Project: 05/87 (May 1987)
Start of RCC: 05/88 (May 1988)
End of RCC: 04/89 (April 1989)
End of Project: 01/90 (January 1990)
Country: USA
River: Colorado
DMS Co-ordinates: 31˚30'2.03"N, 99˚40'3.49"W
DD Co-ordinates: 31.500565, -99.667633
Facings
Upstream
Slope | Type |
---|---|
Vertical | Reinforced concrete cast against precast units or slip-formed facing elements |
Downstream
Slope | Type |
---|---|
0.831 | Unformed face of RCC |
Spillway
Slope | Type |
---|---|
ogee | Reinforced conventional concrete cast after RCC placement |
Placement
Layers (mm) | Lifts (mm) |
---|---|
300 | 300 |
Cementitious material
Cement (kg/m3) |
---|
125 |
Pozzolan (kg/m3) | Pozzolan Type |
---|---|
62 | High-lime flyash (ASTM Class C) |