Fenhe Nº2
Download PDF data sheet
Particulars
Owner: unknown
Designer: Shanxi Institute of Investigation and Design of Water Conservancy
Contractor: Shanxi Construction Bureau
Statistics
Type: Gravity
Purpose(s): Flood Control / Hydropower / Water Supply
Reservoir capacity: 130 m3x106
Height: 87 metres
Length: 350 metres
Volume of RCC: 362 m3x103
Total volume: 448 m3x103
Construction Dates
Start of Project: 11/96 (November 1996)
Start of RCC: 08/98 (August 1998)
End of RCC: 03/99 (March 1999)
End of Project: 06/00 (June 2000)
Facings
Upstream
Slope | Type |
---|---|
Vertical | Traditional concrete against formwork |
0.20 | Traditional concrete against formwork |
Downstream
Slope | Type |
---|---|
0.75 | Traditional concrete against precast concrete panels |
Spillway
Slope | Type |
---|---|
0.75 | Traditional concrete against formwork |
Placement
Layers (mm) | Lifts (mm) |
---|---|
300 | 3000 |
Cementitious material
Cement (kg/m3) |
---|
127 |
60 |
Pozzolan (kg/m3) | Pozzolan Type |
---|---|
84 | Low-lime flyash (ASTM Class F) |
93 |